FAQ

Search
Question
  • 1 I exported the data from the EzCube, but I can't find it on the PC.

    Please note that EzCube only supports USB drives formatted in FAT or FAT32. If the USB drive is not in the correct format, the device may not recognize it. Make sure to check and format your USB drive accordingly before use.

  • 2 Does EzCube need routine maintenance?

    To ensure optimal performance, we recommend performing an annual check of the light source using the EzCube Verification Kit (P/N: T01-FPBR01-00).

  • 3 Can I perform the custom assay?

    Yes! You can create your own custom assay through the “Standard Assay” application on the EzCube.

  • 4 What kinds of tubes can be used with the EzCube?

    The EzCube is designed to work with 0.5 ml thin-walled PCR tubes made of polypropylene (PP). For best compatibility, we recommend using the 0.5 ml Thin Wall PCR Tube (P/N: T00-FPBR03-00).

  • 5 What kinds of quantification reagents can be used with the EzCube?

    The EzCube Fluorometer is an open system that's fully compatible with EzQuant Quantification Assays as well as other commonly used DNA/RNA quantification kits. This gives you the flexibility to choose reagents that best suit your workflow.

  • 6 How can I ensure proper sample loading when the sample drop is no longer visible after closing the sample arm?

    EzDrop uses a fixed pathlength design. The pathlength does not need to be adjusted when the sample arm is closed, helping avoid compression or deformation of the sample drop caused by pathlength adjustment.
    Before closing the sample arm, the Assist Light helps users check the position and condition of the sample drop. The hydrophobic surface also helps the sample form a stable drop for measurement.
    For consistent measurement performance, regular maintenance of the measurement surface is recommended.

  • 7 How can I ensure proper sample loading when the sample drop is no longer visible after closing the sample arm?

    EzDrop uses a fixed pathlength design. The pathlength does not need to be adjusted when the sample arm is closed, helping avoid compression or deformation of the sample drop caused by pathlength adjustment.
    Before closing the sample arm, the Assist Light helps users check the position and condition of the sample drop. The hydrophobic surface also helps the sample form a stable drop for measurement.
    For consistent measurement performance, regular maintenance of the measurement surface is recommended.

  • 8 Why may EzDrop readings change when repeatedly measuring the same sample drop?

    Micro-volume measurements use very small sample volumes, such as 1 µL. When the same drop is measured repeatedly, small changes in temperature, evaporation, or drop shape can affect the readings. The extent of these effects may vary between instruments due to differences in optical design and measurement methods.
    If you need to measure the same drop repeatedly, wait at least 3 seconds between measurements to minimize the impact of repeated exposure to high-intensity light. For more consistent and reproducible results, we recommend wiping the measurement surface and loading a fresh sample drop for each measurement.

  • 9 Why may EzDrop readings change when repeatedly measuring the same sample drop?

    Micro-volume measurements use very small sample volumes, such as 1 µL. When the same drop is measured repeatedly, small changes in temperature, evaporation, or drop shape can affect the readings. The extent of these effects may vary between instruments due to differences in optical design and measurement methods.
    If you need to measure the same drop repeatedly, wait at least 3 seconds between measurements to minimize the impact of repeated exposure to high-intensity light. For more consistent and reproducible results, we recommend wiping the measurement surface and loading a fresh sample drop for each measurement.

  • 10 Can EzDrop measure samples containing methanol or other organic solvents?

    Yes, but the appropriate measurement method depends on the physical properties of the sample.
    Micro-volume measurement requires a stable liquid column. Methanol and other low-surface-tension solvents may make it difficult to form a stable liquid column with a 1 µL sample. If this occurs, try increasing the sample volume to 2 µL.
    If a stable liquid column still cannot be formed, use the cuvette mode on EzDrop 1000C, which does not rely on liquid column formation on the micro-volume pedestal.