TurboFuge

高速微量離心機

TurboFuge是一款精巧的高速微量離心機,提供24孔及36孔兩種轉子選項,便於用戶進行更具彈性及高效率的樣品處理。TurboFuge具備多重安全設計與低噪音特色,讓用戶享有安全與舒適的工作環境。其卓越的散熱設計,可抑制離心室內溫度上升、保護敏感樣品。

single-product-01

功能特色

feature-1

A Robust Metal Chamber

the solid construction of the metal chamber provides stability and ample protection from the hazard of rotor imbalance
feature-2

The Autoclavable Aluminum Rotor

withstands strong acids and bases to ensure an unlimited life cycle
feature-3

The Motorized Dual Lock

ensures that the lid is always safely locked when the rotor is running
feature-4

Intelligent Imbalance Detection

The rotor imbalance sensor turns the centrifuge off immediately if rotor imbalance is detected
feature-5

Lid Drop Protection

The lid is held at 30-40 degrees to allow easy loading and unloading of tubes.

產品規格

  • Max. Speed
  • 15,000 rpm
  • Max. RCF
  • 21,400 x g
  • Max. Capacity
  • 24 x 1.5/2.0 ml
  • Acceleration Time
  • 15s
  • Deceleration Time
  • 16s
  • Timer
  • 30 seconds to 9 hours:59 minutes, with continuous mode
  • Safety
  • Metal chamber, aluminum rotor, motorized dual lock, imbalance detection, lid drop protection
  • Power Supply
  • VAC 100-240, 50/60 Hz
  • Power Requirement
  • 230 W
  • Dimensions (W x D x H)
  • 29 x 48 x 26 cm
  • Weight without rotor
  • 10 kg
  • Certifications
  • CE, RoHs

* Specifications are subject to change without prior notice.

訂購資訊

  • AAMC-2410
  • TurboFuge with aluminum rotor and plastic lid
  • AAMC-a001
  • Metal lid

資源下載

常見問題

  • 1 How do I set the Speed and Time for a spin?

    Press the Speed button and rotate the knob to select the speed. Time is adjusted in the same way.

  • 2 What does RCF mean? How do I convert RPM to RCF?

    RCF (Relative Centrifuge Force) is a measure of the centrifugal force exerted by the centrifuge. It can be calculated using the formula shown below:

    RCF or G-force = 1.12 x Radius x (RPM/1000)²

  • 3 What does the “System” key on the front panel do?

    Pressing the System key gives access to five system settings, AUTO LID, ALM, SLOW, CP and SPIN.
    ● AUTO LID: When Auto-lid is selected, the centrifuge lid will open automatically at the end of a run.
    ● ALM: The alarm volume can be adjusted in ALM.
    ● SLOW: This function activates slow (soft) acceleration and deceleration of the motor. This is useful for experiments with sensitive reagents or samples. For an upgraded/standard model, there are 9/2 ramps for selection.
    ● CP: This is the count up function. When CP is on the system it will count the time after a run has been completed.
    ● SPIN: This allows the maximum speed reached during a Short/Spin to be set.

  • 4 What is the function of the Auto-lid (AUTO LID)?

    When Auto-lid is on, the lid of the centrifuge will open automatically at the end of a run.

  • 5 What is the function of the count up (CP)?

    This will tell you how long your sample stays in the chamber after a run has been completed.

  • 6 What does Short/Spin do?

    The Short/Spin button starts the centrifuge running and it will continue to run as long as the button is held down. A short spin is usually used to collect the liquid in the tube. The short spin speed can be set in the System.

  • 7 How is the Short/Spin speed adjusted?

    The Short/Spin speed is set via the System. Press “Speed” on the main screen. Turn the knob to the required speed and press enter. Then find the “SPIN” function in the “System” and select “On” to confirm.

  • 8 Why is it necessary to hold the lid for half a second for the latch to close?

    This is a safety feature to ensure that the lid has been closed intentionally.

  • 9 I feel air flow underneath the lid during centrifugation. Is that normal?

    Yes, it is normal. There is a cooling fan in the lid and the chamber is sealed when the lid is locked.

  • 10 I can hear the fan running when the centrifuge is in idle mode, is that normal?

    Yes, it is normal. The fan in the centrifuge cools the chamber to prevent heat accumulation. The fan continues to run at a low speed when the rotor is not running.

  • 11 What is the purpose of the ventilation slits on the top of the centrifuge lid?

    These slits allow excessive heat to escape when the centrifuge is running at a high speed and this keeps the heat in the chamber to a minimum.

  • 12 Can I change the speed and time during centrifugation?

    Yes, you can change the speed and time during centrifugation.

  • 13 Can I do a slow (soft) ramp in this centrifuge?

    Yes. You can set the centrifuge to 9 different ramps. The acceleration and deceleration times can be set from 15 to 90 seconds

  • 14 Will the temperature of the sample inside the chamber at maximum speed increase over time?

    The sample temperature (equivalent to the chamber temperature) will increase by no more than 12ºC above ambient temperature after 1 hour of centrifugation at maximum speed.

  • 15 Does the centrifuge need calibration?

    No. The rotor is driven by a brushless DC motor that does not need calibration.

  • 16 Does the centrifuge need regular maintenance?

    Yes, it does. Regular maintenance includes checks on possible chemical damage. It can extend the maximum operating life of the centrifuge.

  • 17 What kind of maintenance is necessary?

    The rotor and chamber should be cleaned with a moist cloth and neutral detergents after use and on a weekly basis. In the event of a spill, or contamination of the rotor and chamber by aggressive liquids, it should be cleaned immediately. The rotor and lid can be autoclaved. But never autoclave the rotor with the lid attached.